How do I change how often the Knowledge Consistency Checker runs?
John Savill
April 13, 2000
1 Min Read
A. The Knowledge Consistency Checker (KCC), which manages connection objects for inter- and intrasite replication, runs every 15 minutes by default. To change this time period, start regedit and go to the HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesNTDSParameters Registry entry.
From the Edit menu, select New, DWORD Value. Enter
Repl topology update period (secs)
and press Enter. Double-click the new value, and enter the number of seconds for how often you want the KCC to run. Click OK, then close the Registry editor. Restart the machine for the change to take effect.
About the Author
Sign up for the ITPro Today newsletter
Stay on top of the IT universe with commentary, news analysis, how-to's, and tips delivered to your inbox daily.
You May Also Like