When you exit an MS-DOS program, Windows 2000 issues:
Invalid COMMAND.COM Cannot load COMMAND, system haltedThe MS-DOS windows stops responding.
The problem occurs because the ComSpec environment variable is not set to a CMD.EXE file.
To resolve the issue:
1. Close the hung window or use Task Manager to End Task.
2. Use Notepad to edit %SYSTEMROOT%\SYSTEM32\AUTOEXEC.NT.
3. If a ComSpec= line exists, remove it.
4. Start / Settings / Control Panel / System / Advanced / Environment Variables.
5. Select the ComSpec line and press Edit.
6. Set the ComSpec Environment Variable to:
%SystemRoot%\system32\cmd.exe