Skip navigation

JSI Tip 0815. SP4 interferes with Workstation Power Management.

If you have Power Management on your NT 4, SP4 Workstation, chances are that it no longer functions.

With SP4, a Windows NT Server function writes a time stamp to the the hard drive approximately every 5 minutes in order to approximate system shutdown time in the event of improper shutdown.

Unfortuneatly, this feature is turned on by default, even on a workstation. To disable it, navigate to:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion

With the Current Version key selected, Add Key name Reliability (unless already present) with a Class of REG_DWORD. Select the Reliability sub-key and Add Value name TimeStampInterval as a type REG_DWORD and set the data value to 0.

You will need to restart your workstation.